Reactive Loading and Amplifier Distortion
section 10 of article —
Referring to the complex impedance of a loudspeaker, Vance Dickason states [2] that, “Phase angles in excess of 40° at low frequencies, and the same at frequencies about 1-2 kHz, can be considered as a somewhat difficult load for an amplifier to drive.” Also on p.129 of the same book he says “The extent to which the load is either capacitively or inductively reactive at different frequencies determines how happy or unhappy an amplifier will be driving a particular loudspeaker.”
Michael Renardson in his paper [3] states that, “Although many loudspeakers are specified as having an impedance of 8Ω there is usually large variation throughout the audio frequency range with typical variations in a given loudspeaker from 5 to 40 ohms and significant reactive components. The distortion produced by an amplifier with a loudspeaker load will therefore be different from that with an 8 ohm resistor and the total harmonic distortion figure is typically 10 dB higher over much of the frequency range and in some cases considerably worse.”
Impedance of woofer LS1 of Figure 4 equals 10Ω at a frequency of 150 Hz, increases to a maximum of 29Ω at 80 Hz and equals 21Ω at 60 Hz. Thus, without excessive impairment of the accuracy of the analysis, the phase angle and impedance of the load presented to an amplifier driving the speaker system of Figure 4 can be calculated disregarding the impedance of LS1 connected across the series connection of capacitors C1~ C4 and resistor R2. At frequency equal to 40 Hz and 55 Hz, phase angle of the response-shaping network consisting of resistor R1, capacitors C1~ C4 and resistor R2 equals (respectively) 45° and 36°. At frequencies greater than 500 Hz the phase angle is 0°. Impedance of the response shaping network at frequency equal to 40 Hz and 500 Hz is respectively 6.4Ω and 4.5Ω.
For frequency equal to or greater than the cut-off frequency f3 of the system of Figure 2 or 55 Hz, the phase angle of the load of that system is less than 40° and thus according to Dickason should be less of a difficult load for an amplifier to drive than is sometimes encountered. Variation of impedance of the system of Figure 2 is only from about (slightly less than) 4.5Ω to 6.4Ω which is much less of an impedance swing than normal. The small impedance swing of the system of Figure 2 presumably reduces total harmonic distortion based on the statement of Renardson.
http://sound-au.com/articles/pikku9.htm
Reactive loading in amplifiers refers to the use of reactive components, such as capacitors and inductors, in the output stage of the amplifier to modify its behavior. This technique is often employed to optimize the amplifier’s performance under different operating conditions and loads. However, reactive loading can also introduce certain challenges, including amplifier distortion.
Here’s how reactive loading can affect amplifier distortion:
1. Phase Shift: Reactive components introduce phase shifts in the output signal of the amplifier. This phase shift can affect the overall phase response of the amplifier and lead to distortion, especially at higher frequencies where the phase shifts become more significant.
2. Impedance Mismatch: Reactive components can cause impedance mismatches between the amplifier and the load. When the impedance of the load does not match the amplifier’s output impedance, it can lead to reflections and standing waves in the transmission line, causing distortion and signal degradation.
3. Frequency Response: Reactive loading can affect the frequency response of the amplifier, particularly in the presence of reactive elements with frequency-dependent characteristics, such as capacitors and inductors. Changes in the frequency response can result in nonlinear distortion and alterations to the signal waveform.
4. Nonlinear Behavior: Reactive components can exhibit nonlinear behavior under certain conditions, especially when subjected to high voltages or currents. Nonlinearities in the reactive components can contribute to harmonic distortion and other forms of nonlinear distortion in the amplifier output.
5. Transient Response: Reactive loading can impact the transient response of the amplifier, affecting its ability to accurately reproduce fast-changing signals. Poor transient response can result in distortion and ringing artifacts in the amplifier output.
To mitigate distortion caused by reactive loading, amplifier designers often employ techniques such as impedance matching, compensation networks, and careful selection of reactive components to minimize phase shifts and impedance mismatches. Additionally, feedback loops and signal conditioning circuits may be used to correct for distortions introduced by reactive loading and maintain the desired performance of the amplifier. Overall, understanding the effects of reactive loading on amplifier distortion is crucial for optimizing amplifier design and performance in various applications.